EVERDRY® heat-regenerated adsorption dryers

Plant concepts with many variations

EVERDRY distributor
EVERDRY FRP/FRA/FRL

Our three basic concepts combine tried and tested process technology with advanced plant and control features that are suitable for optimised operation in any climate zone.

Read more...
EVERDRY combitroc
EVERDRY CT

The EVERDRY COMBITROC CT series is the perfect combination consisting of a refrigeration dryer and an adsorption dryer.

Read more...
EVERDRY HOC P
EVERDRY HOC

The models of the EVERDRY HOC series can be used in all systems where compressed air is produced without oil. Its main advantage: the heat generated in the compression process is not simply dissipated in the aftercooler as is the case in conventional units,but used for desorption.

Read more...

EVERDRY® FR: flexible - Regeneration utilising blown air

Desorption by utilising heated blown air is the fundamental principle for the EVERDRY FR basic concept. The system unifies tried and tested process technology with state of the art plant, system and control system engineering. Three standardised, but still very variable, basic concepts are currently available. These are universally implementable and have proven themselves in all climatic zones. Control and pneumatic cabinets are located with all basic concepts on the front of the system for simplified operation, trouble-free control and maintenance. 23 models cover performance stages from 580 up to 20,000 m³/h, higher volume flows can be implemented on request.

EVERDRY® FRA ambient air: Cooling utilising ambient air

Desorption with EVERDRY FRA is executed in the counter-current to the adsorption direction with heated blown air and cooling by utilising blown air in the direct current. No compressed air losses therefore result for regeneration (ZERO Purge). Utilising this adsorption dryer is dependent on the ambient conditions, which must be inspected before every application.

EVERDRY® FRL Loop: encapsulated cooling air routing

Desorption with EVERDRY FRL is executed in the counter-current to the adsorption direction with heated blown air and cooling by utilising blown air in the direct current in an encapsulated cooling circuit (loop). The cooling stage is therefore created independently of the ambient conditions, which means that this adsorption dryer can be utilised worldwide in every climatic zone. Compressed air is not required for the cooling stage (ZERO Purge).

EVERDRY® FRP purge air: Cooling utilising compressed air

The universal and worldwide implementable EVERDRY FRP executes the desorption in the counter-current to the adsorption direction with heated blown air and cooling by utilising a relieved, partial flow from the dried compressed air flow.

Advantages of EVERDRY® FR

Energy-optimised concept
  • Flow-optimised single fixtures for minimising pressure losses
  • Energy-efficient dew point control system

Application oriented solutions
  • Total concept instead of just individual components
  • Easy to maintain design
  • Informative and comfortable to use touch panel control system

Reliable process management
  • Safe function monitoring with sensor technology
  • High-quality high-temperature galvanising
  • Tried and tested and maintenance-friendly components

Technical data EVERDRY® FR

  EVERDRY FRA EVERDRY FRA-V EVERDRY FRP EVERDRY FRL EVERDRY FRL-V
Volume flow 4200 – 20000 m³/h 580 – 3400 m³/h 580 – 20000 m³/h 4200 – 20000 m³/h 580 – 3400 m³/h
Operating pressure 4 ... 10 bar [g] 4 ... 10 bar [g] 4 ... 10 bar [g] 4 ... 10 bar [g] 4 ... 10 bar [g]
Inlet temperature 5 ... 43 °C 5 ... 43 °C 5 ... 43 °C 5 ... 43 °C 5 ... 43 °C
Ambient temperature 5 ... 40 °C 5 ... 40 °C 5 ... 40 °C 5 ... 40 °C 5 ... 40 °C
Pressure dew point -40 °C -40 °C -40 °C -40 °C (-70 °C optional) -40 °C (-70 °C optional)
Quality Class -.2.- -.2.- -.2.- -.2.- (-.1.-) -.2.- (-.1.-)

* Further technical data can be found in the product information below in the download area ...

EVERDRY® Combitroc CT- Efficiently combined

The EVERDRY COMBITROC CT series provides the optimal processing combination of a refrigeration dryer and an adsorption dryer. In principle, a refrigeration dryer will provide energy savings and achieve a pressure dew point of +3 °C. A lower pressure dew point is required during colder seasons in order to reliably prevent condensate. The system then automatically switches on the heat-regenerating adsorption dryer, thereby creating a secure pressure dew point of below -40 °C. Another additional advantage of this combination: 100 % back up with failure of one drying unit.

Refrigeration and adsorption in one

The EVERDRY COMBITROC CT is perfectly suited for applications in almost every climatic zone. Desorption is executed in the counter-current to the adsorption direction with heated blown air, the cooling by utilising blown air. Local application conditions and economic parameters ultimately determine the individual, customer-specific project solutions. Higher volume flows can be implemented on request.

Characteristics of the EVERDRY COMBITROCat a glance:

  • Processing unit for setting to Summer or Winter modes
  • Complete concept including pipework, fittings, upstream and downstream filters
  • Adsorption dryer with a back up function means: Can be implemented even when the refrigeration dryer is not available for use.

Advantages of EVERDRY® CT

Energy-optimised concept
  • Beneficial individual fittings
  • Energy-efficient dew point control system
  • Combination dryer

Application oriented solutions
  • Added value by utilising comprehensive competence
  • Total concept instead of just individual components
  • Informative and comfortable to use touch panel control system
  • Easy to maintain design

Reliable process management
  • Safe function monitoring with sensor technology
  • High-quality high-temperature galvanising
  • Tried and tested and maintenance-friendly components

Technical data EVERDRY® CT

Application limits  
Operating pressure 4 ... 10 bar [g]
Inlet temperature 5 ... 43 °C
Ambient temperature 5 ... 40 °C
Maximum blowing suction 35 °C / 40 % resp. 30 °C / 50 % r. h.
Volume flow CT 2600 CT 2900 CT 3400 CT 4200 CT 5000 CT 6000
m³/h bei 6 bar [ü] 2300 2600 3000 3650 4400 5000
m³/h bei 7 bar [ü] 2600 2900 3400 4200 5000 6000
m³/h bei 8 bar [ü] 2925 3150 3800 4650 5650 6400

* Further technical data can be found in the product information below in the download area ...

EVERDRY® HOC: sustainable use of the heat of compression

The EVERDRY HOC plants utilise the existing compression heat from oil-free pressurised, compressed air for the desorption. The is the best, energy-related method for compressed-air drying. Depending on the final compression temperature (between 100°C and 200°C), pressure dew points between -5°C and -40°C can be achieved in this case without any additional energy consumption.

The whole process sequence (adsorption, desorption and cooling) is executed here under operating pressure as opposed to conventional adsorption dryers. In addition to the advantages for energy-related consideration, this creates enormous advantages for the service life of the functional elements: The pressure changing loads on fixtures, pressure vessel, pipework and desiccant are no longer applicable.

Systems and plants with a volume flow of 100,000 m3/h are also feasible on request.

EVERDRY® HOC-F

The desorption in the EVERDRY HOC-F is executed in full flow by exploiting the compression heat and the cooling in the full flow and utilising the cold compressed air volume flow. No compressed-air losses for regeneration (ZERO Purge).

For compressors equipped with or without integrated after cooler.

EVERDRY® HOC-P

The desorption in the EVERDRY HOC-P is executed in the partial flow by exploiting the compression heat and the cooling in the partial flow by utilising the cold compressed air volume flow. No pressurised air losses for regeneration (ZERO Purge).

EVERDRY® HOC-R

The desorption in the EVERDRY® HOC-R is executed in the full flow by exploiting the compression heat. A reload desorption follows as an option for lower dew points. The cooling is executed, without pressure loss, with a partial flow from the dried compressed air. No pressurised air losses for regeneration (ZERO Purge).

Advantages of EVERDRY® HOC

Energy-optimised concept
  • Utilising compression heat
  • No pressurised air losses for regeneration
  • Flow-optimised single fixtures for minimising pressure losses
  • Energy-efficient dew point control system

Application Oriented Solutions
  • Total concept instead of just individual components
  • Easy to maintain design
  • Informative and comfortable to use touch panel control system

Reliable Process Management
  • Safe function monitoring with sensor technology
  • High-quality high-temperature galvanising
  • Tried and tested, easy to maintain heat exchanger design
  • Optional stainless steel version

Durable and Efficient
  • Plants and systems function with operating pressure in every process stage
  • No loads and stresses on components and the desiccant during pressure changes

Technical data EVERDRY® HOC

  EVERDRY HOC-F EVERDRY HOC-P EVERDRY HOC-R
Volume flow Anlagen bis 100.000 m³/h auf Anfrage Anlagen bis 100.000 m³/h auf Anfrage Anlagen bis 100.000 m³/h auf Anfrage
Operating pressure 4 ... 10 bar [g] 5 ... 10 bar [g] 4 ... 10 bar [g]
Inlet temperature 5 ... 43 °C 5 ... 43 °C 5 ... 43 °C
Ambient temperature 5 ... 40 °C 5 ... 40 °C 5 ... 40 °C
Pressure dew point -40 °C -40 °C -70 °C
Quality Class -.2.- -.2.- -.1.-

* Further technical data can be found in the product information below in the download area ...

From the idea to the custom-made solution

EVERDRY offers standardised plant concepts with a wide range of variation possibilities. In this manner, the complex tasks of compressed-air drying of large volume flows are solved particularly economically. Special, customer-specific requirements are met with individual solutions. In this respect, it is not the available technology that determines the concept of a drying system but the solution-oriented, optimum technology.

Downloads EVERDRY FR

Brochure
PDF
966 KB
EVERDRY FRA
Brochure
PDF
950 KB
EVERDRY FRA V
Brochure
PDF
946 KB
EVERDRY FRA V plus
Brochure
PDF
1 MB
EVERDRY FRL
Brochure
PDF
1,001 KB
EVERDRY FRL V
Brochure
PDF
1 MB
EVERDRY FRP

Downloads EVERDRY CT

Brochure
PDF
918 KB
EVERDRY Combitroc CT

Downloads EVERDRY HOC

Brochure
PDF
2 MB
EVERDRY HOC F
Brochure
PDF
1 MB
EVERDRY HOC F 2
Brochure
PDF
951 KB
EVERDRY HOC P
Brochure
PDF
1 MB
EVERDRY HOC R

Something missing?

You miss something here in the download area? We're here to help, just let us know:

Send information inquiry....

DRYPOINT AC

The dryers of the DRYPOINT AC series use top-quality desiccants, guaranteeing reliable supply of compressed air of the highest quality. The desiccant adsorbs moisture to a pressure dew point as low as -40 °C (optional -70 °C), thus ensuring trouble-free and efficient production.

Read more...